Vertical Belt Linear Actuator Design with Brake Counterbalance and Safe Stop

Date:2026-11-09 Click:108

A vertical belt driven linear stage needs more than enough motor torque to lift its payload. The design must also account for what happens when drive torque disappears, a brake fails to engage, or an emergency stop interrupts movement. A moving load may continue descending under gravity even after a stop has been requested.

The key distinction is between holding an axis at rest and bringing a moving axis to a stop. A holding brake, a controlled stopping function and a counterbalance serve different purposes. None independently establishes fall prevention or replaces a project-specific risk assessment.

The design decision: identify the full gravity load, define normal and fault-related stopping cases, then verify how the machine restrains hazardous movement when the expected sequence cannot complete.

1. Treat vertical holding and dynamic stopping as separate requirements

On a horizontal axis, gravity is often supported by the guide structure rather than acting directly along the travel direction. Rotate the motion vertically, and gravity becomes a continuous force tending to move the carriage downward. An ordinary loss of commanded motion can therefore become a load-retention problem.

Static holding concerns the load at standstill. Dynamic stopping concerns speed, inertia, gravity and energy while the carriage is moving. A brake selected to hold a stopped motor shaft must not be assumed capable of absorbing repeated emergency-stop energy. Likewise, removing drive torque does not create a mechanical support for the carriage.

The basic gravity force is:

Fg = mtotal × g

Here, Fg is gravity force in newtons (N), mtotal is the complete vertically moving mass in kilograms (kg), and g is gravitational acceleration in metres per second squared (m/s²). The equation is a starting point for the load model—not a brake-torque rating, safe stopping distance or approval calculation.

A timing-belt transmission should not be assumed to be self-locking. If motor torque is removed, gravity can drive the belt, pulleys and connected transmission in reverse unless an effective holding arrangement prevents movement. On a vertical axis, the movement before restraint takes effect depends on the drive, brake response and load path. The transmission, brake and any independent restraint must therefore be assessed as one load-retention system.

2. Identify gravity load and foreseeable loss-of-power conditions

The supported mass is rarely just the workpiece. Tooling plates, grippers, hoses, sensors and other moving hardware all belong in the load assessment. When a vertical axis carries an upper-axis assembly, that assembly and its changing payload may also contribute. The center of gravity should be recorded because an offset load introduces guide and mounting moments even when the lifting force appears acceptable.

Operating position and personnel access change the hazard. A suspended tool above an accessible loading station requires a different exposure assessment from an axis enclosed behind effective guarding. Maintenance, cleaning and fault recovery may introduce access conditions that do not occur during automatic operation.

Power-loss analysis should cover a carriage stopped with a load, a commanded downward move, a lift in progress and an interruption during brake release or engagement. The central question is what restrains motion if motor torque disappears before the holding system takes over.

A belt-driven stage may still be appropriate where long travel and fast transfer are important, but its ability to move the load is only one part of the decision; vertical load retention must be designed separately. If the application places greater emphasis on axial thrust, rigidity or controlled vertical positioning, a screw-driven module may also merit evaluation. Neither transmission should be assumed to hold a suspended load without checking the selected configuration and its protective measures.

At this stage, the STM Series belt driven linear module is a relevant series to review for mechanical integration. Its range includes belt-drive modules for general automation, but the selected model's vertical mounting conditions, brake interface and load limits still require verification. A series listing is not proof of an approved vertical configuration.

STM Series: Construction Reference

This official SAHO STM120 image illustrates a belt-driven module structure. It does not depict a verified vertical brake or counterbalance configuration, and is not a recommendation to use STM120 vertically.

SAHO STM120 belt-driven linear module product reference

Reference image only. Confirm vertical orientation, model data and protective measures before selection.

View STM120 Product Details

3. Compare holding brake and counterbalance functions

A brake and a counterbalance can work in the same vertical-axis design, but they solve different mechanical problems. The brake restrains motion under its specified engagement conditions. A counterbalance reduces the residual gravity force the drive or holding arrangement must resist. Neither should be selected solely from the unloaded actuator dimensions.

Brake duty and release sequence

A motor holding brake is commonly intended to engage once the axis has stopped. A device used to decelerate a moving load needs manufacturer-approved dynamic stopping capability, including appropriate energy and duty ratings. Repeated emergency engagements can damage a holding-only brake if the manufacturer has not permitted that duty.

Timing matters as much as nominal capacity. During a normal start, adequate drive torque must support the gravity load before brake release. During a planned stop, load control must be maintained until the holding mechanism engages. If power disappears mid-sequence, the result depends on the actual brake response, available energy and independently provided protective measures.

Counterbalance travel and failure cases

A counterweight, spring mechanism or other engineered balancing device may reduce the force that the drive must overcome. For a simplified vertical force balance:

Fnet = mtotal × g − Fcb

In this signed model, Fnet is residual vertical force (N), and Fcb is upward counterbalance force (N). A positive result means a net downward force; a negative result means a net upward tendency. The relationship assumes a defined load path and does not account for transmission losses or transient dynamics.

Counterbalance sizing must account for the full payload range, not just the heaviest operating condition. A setting that nearly balances a fully loaded carriage may pull an empty carriage upward, while a lighter setting may leave a substantial downward force at maximum payload. The force profile should therefore be checked throughout the stroke, including how the system behaves if a spring, cable or pressure source fails.

For background on transmission trade-offs, SAHO's belt and ball screw drive comparison helps clarify why drive choice and vertical load control should be treated as separate questions. It does not establish the safety of either arrangement.

4. Define the controlled-stop and power-loss scenarios

A normal stop can use controlled deceleration before a holding mechanism secures the stationary axis. An unexpected power loss may interrupt that sequence. The design must therefore distinguish what can be achieved while motor torque remains available from what prevents hazardous motion once it is unavailable.

For an idealized stop with a constant initial-speed delay followed by constant net deceleration:

s = v0td + v02 / (2a)

Here, s is travel to standstill (m), v0 is initial speed (m/s), td is delay before effective deceleration (s), and a is the positive magnitude of constant net deceleration (m/s²). The estimate applies only when those assumptions hold. It is not a universal emergency stopping distance or a model for uncontrolled descent.

The machine's stopping concept should address:

  • Normal stopping: commanded deceleration and a defined transfer to stationary holding.

  • Protective stopping: the safety-related function and mechanical measures required for the assessed exposure.

  • Power or control faults: brake engagement behavior when drive torque, control power or feedback is lost.

  • Mechanical faults: the consequences of failures in the belt path, coupling, brake or counterbalance connection.

Safety boundary: Safe Torque Off (STO) removes the drive's ability to generate motor torque; by itself, it does not actively decelerate the axis or mechanically hold a suspended load. Where a safety-related controlled stop is required, a drive-supported function such as Safe Stop 1 (SS1) may initiate deceleration before STO is activated. Safe Brake Control (SBC), where supported and correctly integrated, is used to control a holding brake; it does not make an unsuitable brake suitable for dynamic stopping. The complete sequence, brake response and failure conditions must be assessed and validated at machine level.

5. Collect evidence before vertical installation approval

The feasibility review becomes productive when assumptions are separated from verified data. A declared payload is a project requirement, not evidence that the proposed belt drive or brake can support it vertically. Similarly, a motor brake's catalog designation does not establish its permitted dynamic duty.

Vertical Axis Operating and Stop Requirements Checklist

Use this checklist to prepare the application handoff between the machine designer, actuator supplier and project safety reviewer. Separate confirmed specifications from outstanding engineering questions before model selection.

Review fieldApplication data to collect
Axis geometryProposed orientation, mounting layout, working stroke (mm), travel limits.
Gravity loadMinimum/maximum moving mass (kg), tooling and upper-axis mass; center-of-gravity offset (mm).
Motion profileUp/down speed (mm/s), acceleration and deceleration (mm/s²), duty and positions.
Brake interfaceProposed brake type; verified holding/dynamic ratings, timing, control and fault behavior.
CounterbalanceType, force-versus-travel characteristics (N), attachment and failure conditions.
Fault scenariosPower loss, drive fault, emergency stop, brake failure and mechanical disconnection.
EvidenceExact model drawings, installation instructions, component ratings, personnel exposure and project risk assessment.

The available evidence must identify the specific actuator model, permitted installation direction, transmission and guide limitations, and the proposed brake or independent restraint arrangement. Any outstanding item should remain open until supported by supplier documentation and the machine-level engineering review.

If the machine has a separate high-speed, long-stroke transfer axis, the TA Series is a relevant option to review for that role. SAHO describes TA around fast transfer and material handling; its listing does not establish vertical-use suitability, a standard brake configuration or interchangeability with STM.

Engineering handoff: complete the checklist, attach the current axis drawing and mark unknown ratings as engineering confirmation required. This is the appropriate starting point for an application review, not an installation approval.

The completed checklist can accompany an engineering review request to SAHO. Supplier input should be considered alongside the machine-level risk assessment.

6. Ask for an STM vertical-use feasibility review

The STM Series is the intended commercial path for this article, but no individual STM model has been confirmed for the proposed vertical duty. An application review should establish whether the candidate module's permitted orientation, load envelope, transmission layout and motor integration can accommodate the machine concept before a complete braking solution is specified.

The request should identify the expected normal stop, protective stop and power-loss response, alongside the moving mass and available counterbalance data. Any proposed brake, restraint or control arrangement still requires project-level risk assessment and validation. Product-series documentation supports selection; it is not a safety certificate for the finished machine.

Frequently Asked Questions

Is a holding brake designed for repeated emergency stops?
Not necessarily. Many motor holding brakes are intended for stationary holding. Repeated dynamic stopping is acceptable only when the manufacturer explicitly rates the selected brake for the required energy and duty.
Does removing motor torque prevent a gravity drop?
No. Torque removal does not mechanically restrain a suspended load. Appropriate load-holding or other protective measures must be established for the assessed fault conditions.
Can a counterbalance replace risk assessment?
No. It changes the force balance but introduces its own travel, attachment and failure cases. The complete machine still needs a project-specific risk assessment.
What must be confirmed before using STM vertically?
Confirm the selected model's permitted installation orientation, load and moment limits, drive and brake integration, supplier instructions, and the machine's validated stopping and fall-prevention measures.

For a vertical belt driven linear stage, the decisive question is not whether the motor can lift the load. It is whether gravity is controlled at standstill, during commanded deceleration and when the expected power or braking sequence fails. That answer comes from the actual load model, verified components and machine-level safety review.


Continue the STM Feasibility Review

Bring the completed load and stopping-requirements checklist, the current axis drawing and any missing brake or counterbalance information. Review the STM range against that application data before making a model-selection or safety decision.

Review STM Series with Your Application Data

Compare STM options against the defined moving load, mounting direction, motion profile and stopping requirements. Share the axis drawing and any outstanding brake or counterbalance information to support the engineering review.

Review STM SeriesContact SAHO for Engineering Review