| A ball screw linear axis can position accurately during initial testing yet drift after hours of repeated operation. The way the screw is supported at each end is one factor that can explain this change. A fixed–floating arrangement locates the screw axially at one end and allows axial movement at the other, while a fixed–fixed arrangement restrains both ends and may offer greater axial stiffness. The choice affects both the deflection under load and the way the axis responds to heat. |
Consider an inspection axis that repeats the same move throughout a production shift. If its carriage gradually moves away from the expected measurement position as the machine warms, the problem may not be backlash or screw accuracy alone. The screw and its supporting structure may be expanding at different rates.
This is why stiffness under load and positioning accuracy at operating temperature are worth considering together. A support arrangement that performs well in a cold test may behave differently after sustained operation.
How End Supports Influence Axial Rigidity
When the ball nut moves a carriage, the corresponding axial reaction has to travel through the screw, bearing assembly, housing and machine frame. Each interface contributes to the overall deflection. A bearing with high catalog stiffness does not make the complete axis rigid if the surrounding bracket or frame bends under load.
In a conventional fixed–floating design, the locating bearing assembly resists thrust and establishes the screw’s axial reference. The other end provides radial support without preventing the intended axial movement. As the nut moves farther from the locating end, a greater length of screw carries the axial load, so the screw itself can contribute more to the deflection.
| A practical stiffness relationshipδ = F / kaxδ = axial deflection (mm); F = applied axial force (N); kax = effective stiffness of the complete axial load path (N/mm). This is a simplified, approximately linear-elastic relationship, not an SR product rating. |
For the same applied force, doubling the effective stiffness halves the elastic deflection in this simplified relationship. Fixed–fixed support can reduce the screw’s contribution to that deflection because both ends may share the load. The benefit still depends on the nut position and the stiffness of the bearings and mounting structure.
How Fixed and Floating Supports Work
The difference between a fixed and a floating end is not simply the type of bearing installed. It lies in how the bearing rings, shaft and housing are assembled, and whether that assembly allows the screw to move axially.
Bearing Arrangement
A fixed end generally locates the screw in both thrust directions, often through a paired bearing arrangement and suitable shaft retention. At the other end, a radial support can allow axial movement through an appropriate bearing or fit. A deep-groove bearing, for example, is not automatically a floating support: if both rings are retained in a way that prevents the intended movement, the assembly may restrain the screw.
In a complete ball screw-driven linear stage, these details are not always visible from the outside. For example, when comparing SAHO’s SR Series ball screw linear modules, including the SR45 and SRW45, the model drawing is the appropriate source for identifying the actual end-support arrangement and mounting interfaces.
Axial Location and Housing Interfaces
Small assembly details can change how a support behaves. A shaft shoulder, locknut, spacer or retaining ring may close the clearance intended for axial movement. Bearing-ring fits and housing geometry also determine whether the movement is possible. The motor coupling is a separate consideration: its ability to accommodate small misalignments does not necessarily mean it can accommodate the screw’s thermal travel.
Together, these details explain where the screw is located relative to the axial datum, how thrust reaches the frame and, in a fixed–floating design, where thermal movement can occur.
What Happens When the Ball Screw Heats Up?
A floating end gives the screw room to lengthen as it warms, reducing the risk of unwanted axial restraint. The trade-off is that the nut can still shift relative to the machine datum as the screw expands. Under uniform free expansion, positions farther from the locating end generally experience greater thermal displacement.
When both ends restrain axial movement, differential expansion between the screw and frame can instead change the internal axial force, affecting the mechanical behavior of the assembly.
Support Layout and Thermal Displacement Path Conceptual engineering sketch — not an SR model drawing and not to scale. FIXED–FLOATING Fixed endAxial locationBall screwThermal growth →Floating endRadial support Axial thrust is resisted by the locating assembly. Relative thermal movement is accommodated at the non-locating interface. FIXED–FIXED Fixed endAxial restraintBall screwRestrained growthFixed endAxial restraint Expansion cannot be treated as free end travel. The resulting change in axial force depends on restraint stiffness, initial tension and relative thermal growth. The distinction is between allowing relative axial movement at one support and restraining it at both ends. |
For a uniform temperature change, the free expansion of a screw segment can be estimated using the following relationship:
| ΔLfree = α × L × ΔTΔLfree: free length change (mm); α: linear expansion coefficient (1/°C); L: original segment length (mm); ΔT: temperature change (°C). Assumes uniform temperature and unconstrained expansion. |
For example, a 500 mm steel screw segment subjected to a uniform temperature increase of 10°C would have an estimated free expansion of approximately 0.06 mm (60 µm), assuming a typical steel expansion coefficient of 12 × 10−6/°C. Even a modest temperature change can therefore matter in precision positioning. This is a theoretical example, not an SR product specification or a prediction of actual positioning error.
In an operating machine, the screw, bearings and frame rarely warm at exactly the same rate. The calculated free expansion therefore gives an indication of scale, rather than the actual carriage error. What matters for positioning is how the screw grows relative to the machine’s measurement reference.
The operating cycle also matters. Screw lead and travel speed determine the required rotational speed, as explained in our ball screw lead and speed calculation guide. That relationship helps define the operating conditions for a thermal assessment, although it does not determine the expansion allowance on its own.
In a floating arrangement, the available axial travel at the non-locating interface has to accommodate the expected relative growth between the screw and frame. A nominally floating support offers little benefit if that travel runs out during operation.
Fixed–Floating vs Fixed–Fixed: Which Layout Makes Sense?
The choice between the two layouts becomes clearer once the working load and operating temperature are considered. A fixed–fixed arrangement may provide a stiffer axial load path, but its behavior also depends on how the screw and frame expand relative to each other.
| Axial reference | Fixed–floating: one locating end.Fixed–fixed: axial restraint at both ends. |
| Temperature change | Fixed–floating: designed travel accommodates screw growth.Fixed–fixed: restraint may change internal axial force. |
| Main evidence | Fixed–floating: bearing retention and permitted axial movement.Fixed–fixed: bearing arrangement, pretension and thermal-force review. |
Stiffness figures are most meaningful when they refer to comparable loads, nut positions, screw geometry and operating conditions. A measurement taken close to one support on a cold machine, for instance, does not necessarily describe the same axis near mid-stroke after warm-up.
For a long transfer axis that runs through substantial temperature changes, fixed–floating support can be a practical way to accommodate growth. The positioning tolerance across the stroke then determines whether the remaining thermal displacement is acceptable.
A short-stroke assembly axis subjected to significant process thrust may place greater emphasis on axial stiffness, making fixed–fixed support worth considering. In a pretensioned design, however, a screw that expands more than its supporting structure can lose some initial tension and, under sufficient restraint, develop compression. That is why the stiffness advantage cannot be assumed to remain constant throughout the operating cycle.
Neither layout is universally better: the relevant question is how much elastic deflection and thermal position change the application can tolerate.
Why Positioning Can Change After Warm-Up
Even a suitable layout can behave differently after installation. A misaligned housing, an incorrectly seated bearing or distortion in the mounting frame can restrict movement that was intended to remain free.
A cold-to-warm comparison is useful here. Measuring the carriage at the same commanded positions before and after representative operation, while recording temperatures near the support housings and accessible reference points, can reveal changes that a cold test misses. Keeping the measurement datum, load and motion cycle consistent makes the results easier to interpret. For a precision axis, an independent position measurement can reveal physical displacement that motor encoder feedback alone may not show.
A change with temperature does not automatically prove the end support is wrong. The screw and frame may expand differently; bearing conditions, alignment and control effects can also contribute. If the symptom includes reversal error, SAHO's separate discussion of preload and backlash effects helps distinguish mechanical lost motion from thermal position drift without treating them as interchangeable.
If the mounting space or access to the screw drive is also a factor, it can be more useful to compare complete module designs than to consider the bearing arrangement in isolation.
RELATED SERIES · SAHO SDM SDM Series Ball Screw Linear ActuatorThe SAHO SDM Series provides another ball screw actuator format to compare when mounting space and access influence module selection. The product image illustrates its external construction; the model drawing is the basis for comparing its internal support arrangement with SR. SAHO SDM Series — external product appearance. |
The warm-up comparison helps narrow the investigation, although measurements alone may not establish whether the cause is the assembly or the support layout.
Evaluating the SR Series for Your Application
When selecting an SR Series module, the required load, stroke, mounting space and allowable positioning error provide a useful starting point. The importance of end support becomes clearer once those requirements are considered alongside the expected duty cycle and operating temperature.
A project drawing showing the shaft ends, bearing and housing sections, fits, retainers and mounting frame helps explain how the module will carry thrust. The screw material, dimensioned length, thrust direction, measurement datum and location, and expected operating conditions complete the picture. Where axial travel or pretension is part of the proposed design, distinguishing an assumption from a documented model feature avoids misunderstandings during selection.
This makes it possible to discuss the selected module in terms of actual machine performance rather than the support label alone.
Frequently Asked Questions
| Does a floating end eliminate thermal positioning error? |
| No. A floating end can support the screw radially while allowing axial expansion, but the nut’s position may still change as the screw grows relative to the machine datum. |
| Is fixed–fixed support always more rigid? |
| Not necessarily. Effective axial stiffness depends on the screw, bearings, housings, mounting structure, nut position and operating temperature. Thermal expansion can also change the screw’s initial tension. |
| Is warm-up data needed for support review? |
| A preliminary drawing review can begin without it. Warm-up measurements become especially valuable when the machine has a temperature-sensitive positioning requirement. |
| Which bearing and housing drawings are required? |
| Provide shaft-end geometry, the bearing arrangement, ring retention, housing sections and mounting interfaces. Show any permitted axial movement or specified pretension, together with the machine datum. |
Find the Right Ball Screw Linear Module Compare the SR Series against your load, stroke, mounting arrangement and operating temperature requirements. Share your support-layout drawing and positioning requirements with SAHO for further engineering review. |